72 Fibre Alliance MIB Objects
Access
Read-only
Status
Mandatory
Return value
See Table 4 for switch operational states.
connUnitStatus (1.3.6.1.3.94.1.6.1.6)
Overall status of the connectivity unit. The goal of this object is to be the single poll point to check to the
status of the connUnit. If there is any other component that has warning, then this should be set to
warning. Any of these values may occur with any of the connUnitState values.
Syntax
INTEGER
Access
Read-only
Status
Mandatory
Return value
See Table 5 for connectivity unit return values. Return value is OK(3), unless one or more of the
following occurs.
connUnitProduct (1.3.6.1.3.94.1.6.1.7)
The SML attribute Config.Snmp.SysDescr. This is the system description shown on the show
version Telnet screen. It can also be read on the show setup snmp screen and written using the set
setup snmp Telnet screen.
Table 4 Switch operational states
Switch state Return state
online online(2)
offline offline(3)
diagnostics offline(3)
other unknown (1)
Table 5 Connectivity unit return values
Return value Status that can cause return value
warning(4) • One or more cooling fan failed
• Temperature status = Warm
• Any port is down
• Switch offline or in diagnostics mode
failed(5) • Power supply is reporting bad and/or not installed
• All cooling fans failed
• Temperature status = Overheating
• POST failed