78 Fibre Alliance MIB Objects
See Table 6 and Table 7 for connUnitControl values.
connUnitContact (1.3.6.1.3.94.1.6.1.23)
Contact information for this connectivity unit, and is persistent across boots.
Syntax
DisplayString (SIZE (0..79))
Access
Read-write
Status
Mandatory
Return value
The default is <sysContact undefined>. The string size is limited to a maximum of 64.
connUnitLocation (1.3.6.1.3.94.1.6.1.24)
Location information for this connectivity unit, and is persistent across boots.
Syntax
DisplayString (SIZE (0..79))
Access
Read-write
Status
Mandatory
Return value
The default is <sysLocation undefined>. The string size is limited to a maximum of 64.
connUnitEventFilter (1.3.6.1.3.94.1.6.1.25)
This value defines the event severity that is logged by this connectivity unit. All events of severity less than
or equal to connUnitEventFilter are logged in connUnitEventTable.
Syntax
FcEventSeverity
Table 6 connUnitContol read return values
Switch setting Return value
Online Online(6)
Offline Offline(5)
Diagnostics Offline(5)
Other Unknown(1)
Table 7 connUnitContol write control values
Control value Result
Cold Reset(3) Reset
Offline(5) Offline
Online(6) Online
Other Not supported