HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network Management Protocol Reference Guide 85
Return value
See Table 14 for connUnitSensorStatus return values for board temperature. See Table 15 for
connUnitSensorStatus return values for fan status. See Table 16 for connUnitSensorStatus
return values for voltage status.
T
T
T
connUnitSensorInfo (1.3.6.1.3.94.1.8.1.5)
Contains miscellaneous static information about the sensor, such as its serial number.
Syntax
DisplayString
Access
Read-only
Status
Mandatory
Return value
Always returns an empty string
connUnitSensorMessage (1.3.6.1.3.94.1.8.1.6)
Describes the status of the sensor as a message. It may also provide more resolution on the sensor
indication. For example: Cover temperature 1503K, above nominal operating range-
::= { connUnitSensorEntry 6 }.
Syntax
DisplayString
Access
Read-only
Table 14 ConnUnitSensorStatus return values for board temperature
Switch value Return value
Normal OK(3)
Warm Warning(4)
Overheating Failed(5)
Other Unknown(1)
Table 15 ConnUnitSensorStatus return values for fan status
Switch value Return value
Good OK(3)
Bad Failed(5)
Other Unknown(1)
Table 16 ConnUnitSensorStatus return values for voltage status
Switch Value Return value
Good OK(3)
Bad Failed(5)
Other Unknown(1)