EasyManuals Logo

HP StorageWorks 8/20q Reference Guide

HP StorageWorks 8/20q
188 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #84 background imageLoading...
Page #84 background image
84 Fibre Alliance MIB Objects
Return value
See Table 12 and Table 13 for connUnitSensorName return values.
connUnitSensorStatus (1.3.6.1.3.94.1.8.1.4)
The status indicated by the sensor.
Syntax
INTEGER {
unknown(1)
other(2)–The sensor indicates other than OK (warning or failure).
ok(3)–The sensor indicates OK
warning(4)–The sensor indicates warning
failed(5)–The sensor indicates failure
}
Access
Read-only
Status
Mandatory
Table 12 ConnUnitSensorName return for for 8/20q FC Switch and SN6000 Single Power Supply FC
Switch
Table index Return value
1 Power Supply 1 Status
2 Temperature Status
3 Temperature Sensor 1 Value
4 Temperature Sensor 2 Value
5 Temperature Sensor 3 Value
6 Temperature Sensor 4 Value
Table 13 ConnUnitSensorName return values for values for SN6000 Dual Power Supply FC Switch
Table index Return value
1 Power Supply 1 Status
2 Power Supply 2 Status
3 Fan 1 Status
4 Fan 2 Status
5 Temperature Status
6 Temperature Sensor 1 Value
7 Temperature Sensor 2 Value
8 Temperature Sensor 3 Value
9 Temperature Sensor 4 Value

Table of Contents

Other manuals for HP StorageWorks 8/20q

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks 8/20q and is the answer not in the manual?

HP StorageWorks 8/20q Specifications

General IconGeneral
Product TypeFibre Channel Switch
Form FactorRack-mountable
Ports20
Port Speed8 Gbps
Aggregate Switch Bandwidth320 Gbps
Fabric TypeSwitched Fabric
CoolingFan
Fibre Channel StandardsFC-PH, FC-AL-2, FC-FLA, FC-GS-3
Management InterfaceCommand Line Interface (CLI)
Hot-swappable ComponentsPower supplies, fans
Data Transfer Rate8 Gbps per port
Power SupplyAC 100-240 V (50/60 Hz)