144 Fabric Element MIB Objects
Syntax
OBJECT IDENTIFIER
Access
Read-only
Status
Current
Return value
TThe module identification number for the 8/20q FC switch is 1.3.6.1.4.1.3873.1.11. The
module identification number for the SN6000 Stackable Dual Power Supply FC switch is
1.3.6.1.4.1.3873.1.25. The module identification number for the SN6000 Stackable Single
Power Supply FC switch is 1.3.6.1.4.1.3873.1.24.
fcFeModuleOperStatus (1.3.6.1.2.1.75.1.1.4.1.4)
The switch definitions map 1-to-1 with the MIB definitions. This object indicates the operational status of the
module.
• online(1)–The module is functioning properly
• offline(2)–The module is not available
• testing(3)–The module is under testing
• faulty(4)–The module is defective in some way
Syntax
INTEGER {
online(1)–Functional
offline(2)–Not available
testing(3)–Under testing
faulty(4)–Defective
}
Access
Read-only
Status
Current
Return value
See Table 32 for module operational status return values.
fcFeModuleLastChange (1.3.6.1.2.1.75.1.1.4.1.5)
This object contains the value of sysUpTime when the module entered its current operational status. A
value of zero (0) indicates that the operational status of the module has not changed since the agent last
restarted.
Syntax
Table 32 Module operational status return values
Mode Return value
online online(1)
offline offline(2)
diagnostics testing(3)
other faulty(4)