HP StorageWorks 8/20q and SN6000 Fibre Channel Switch Simple Network Management Protocol Reference Guide 79
Access
Read-write
Status
Mandatory
Return value
The switch log level setting. See Table 8 and Table 9 for connUnitEvent-Filter values.
connUnitNumEvents (1.3.6.1.3.94.1.6.1.26)
Number of events currently in the connUnitEventTable
Syntax
INTEGER
Access
Read-only
Status
Mandatory
Return value
An integer indicating the number of events in the connUnitEventTable
connUnitMaxEvents (1.3.6.1.3.94.1.6.1.27)
Maximum number of events that can be defined in connUnitEventTable
Syntax
Table 8 connUnitEventFilter read return values
Security levels Return value
Critical Critical(4)
Warn Warning(6)
Info Info(8)
None Unknown(1)
Table 9 onnUnitEventFilter control write values
Control value Result
Emergency (2) Critical
Alert (3) Critical
Critical (4) Critical
Error (5) Warn
Warning (6) Warn
Notify (7) Info
Info (8) Info
Debug (9) Info
Mark (10) Info
Unknown (1)
None