Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WInstall the program product key in the
RCU.
The Fibre-Remote Copy function is not
installed in the specified RCU.
87346005
WCheck the serial number, SSID and link
address of the RCU, and set the correct
value. Then retry the operation. If the
same error occurs, please contact HP
Technical Support.
Invalid RCU serial number, SSID, Link
Address or Controller ID.
87356005
WDelete all Remote Copy volume pairs of
the specified RCU or SSID, and retry the
operation.
The specified RCU or SSID contains some
Remote Copy volume pairs.
87366005
EPlease contact HP Technical Support.An internal error occurred.87376005
WThe emulation type of the MCU does not
support Continuous Access Synchronous.
If you want to use Continuous Access
Synchronous, please contact HP
Technical Support.
Remote Copy is not supported under the
MCU Controller emulation type.
87386005
WThe MCU NVS status specified by the
host is not active. Set the NVS to on
for the MCU, using any attached host,
then retry the operation.
NVS status of MCU is not active.87396005
WThe RCU NVS status specified by the host
is not active. Use any attached host to
set the NVS to on” for the MCU, then
retry the operation.
NVS status of RCU is not active.87406005
WCheck the path status between the MCU
and the RCU.
The logical paths between the MCU and
RCU are not established.
87416005
WCheck the status of the M-VOL tracks,
and clear the pinned tracks.
Pinned track(s) exists on the M-VOL.87426005
WCheck the status of the R-VOL tracks, and
clear the pinned tracks.
Pinned track(s) exists on the R-VOL.87436005
WThe M-VOL is not available for the
requested operation, because of one or
more of the following reasons:
The volume is blocked.
The volume is under maintenance.
The volume is copying data
(correction copy or drive copy).
The volume is in the correction access
condition.
Check the logical device status of the
specified M-VOL. If the M-VOL is either
under maintenance or copying data,
retry the operation after the process is
completed.
The specified M-VOL condition is not
valid for Remote Copy.
87446005
138 Message (part code group 6nnn)