Table 50 Error codes (part code 6005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the track formats of the specified
M-VOL and R-VOL.
M-VOL and R-VOL Track Formats do not
match.
87606005
WConfirm the following about the M-VOL
and R-VOL.
The emulation type is corresponding.
The capacity is corresponding.
If LUSE volume, the capacity that each
volume combined in LUSE are
corresponding.
If mainframe system, the capacity of
copy target is larger than that of copy
source.
The operation failed, because the status
of specifed volume as following:
The emulation type of M-VOL and
R-VOL do not match.
The capacity of M-VOL and R-VOL do
not match.
If LUSE volume is specifed, the
capacity that each volume combined
in LUSE does not match
87616005
WCheck the device cache status of R-VOL
from host. If it is off, set it on and retry.
If it cannot be set on, please contact HP
Technical Support.
R-VOL Device Cache status is not active.87626005
WCheck the DFW status of the R-VOL from
the host. If it is off, set it on and retry. If
it cannot be set on, please contact HP
Technical Support.
R-VOL DFW status is not active.87636005
WConfirm the status of the specified R-VOL.The specified R-VOL is not usable.87646005
WThe device emulation type of the R-VOL
does not support Continuous Access
Synchronous. Please contact HP
Technical Support.
Remote Copy is not supported under the
R-VOL Device emulation type.
87666005
WThe RCU containing the R-VOL is being
used as the RCU for Continuous Access
Synchronous. Verify the status of the
RCU, if necessary delete the RCU, then
retry the operation.
The RCU is still in another Remote Copy
condition.
87686005
WThe RCU containing the R-VOL is being
used as the RCU for Continuous Access
Synchronous. Verify the status of the
RCU.
The RCU is still in another Remote Copy
condition.
87696005
WClick [OK] to acknowledge the message,
then retry the operation after the cache
has been recovered.
The Cache on the MCU is automatically
recovering. Please wait a few minutes
then retry again.
87706005
WThe pair option change operation failed,
either because a communication error
occurred or because the R-VOL status is
not valid. Verify the status, and view the
License Key window at the RCU side to
check the licensed capacity for
Mainframe Array Management. If the
licensed capacity for Mainframe Array
Management is insufficient, purchase a
license key for a larger capacity.
Change pair operation failed due to
communication error or the R-VOL status
is invalid.
87726005
WResume the pair for the M-VOL, then retry
the operation.
Pair change was refused because M-VOL
is suspended.
87736005
WThe multiplatform feature has already
been installed in the RCU. Verify the
configuration of the RCU.
Multi platform feature already installed
in RCU.
87756005
140 Message (part code group 6nnn)