Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the status of the secondary data
volume.
The specified secondary data volume
must not be:
in an intervention-requested condition
in a protected condition
in an unusable condition
a Business Copy S-VOL or a Business
Copy Z T-VOL
a volume reserved by Business Copy
or Business Copy Z
a volume used by Auto LUN
a Business Copy P-VOL in Swap or
Reverse Copy status
a Business Copy Z S-VOL in Swap or
Reverse Copy status
88196505
ECheck the SSB log, then contact HP
Technical Support.
An I/O error occurred on the secondary
data volume.
88226505
WVolumes reserved by Auto LUN cannot
be specified as primary data volumes.
Check the status of the specified primary
data volume from the host or the SVP.
The specified primary data volume is
already reserved by Auto LUN.
88306505
WVolumes reserved by Auto LUN cannot
be specified as secondary data volumes.
Check the status of the specified
secondary data volume from the host or
the SVP.
The specified secondary data volume is
already reserved by Auto LUN.
88316505
WWait a few minutes and retry the
operation.
Please wait a few minutes and then retry
the operation.
88326505
WWait for a few minutes and retry the
operation.
Please wait a few minutes and then retry
the operation.
88336505
WSee license key information and check
the licensed volume capacity. To create
more pairs, please purchase a license
key for using larger capacity.
The Add Pair (Paircreate) operation
failed because you tried to create volume
pairs which exceeded the licensed
capacity.
88346505
WSee the license key at the secondary
storage system and check the licensed
capacity of volumes. To create more
pairs, please purchase a license key for
larger capacity.
The Add Pair (Paircreate) operation
failed because you tried to create volume
pairs which exceeded the licensed
capacity of the secondary subsystem.
88356505
ECheck the SSB log, then contact HP
Technical Support.
An internal error occurred.88876505
ECheck the SSB log, then contact HP
Technical Support.
An internal error occurred.88886505
WRefresh the window, and retry the
operation. If nothing changes, please
contact HP Technical Support.
The specified port is not equipped.88896505
WWait until the initialization of the port
ends, and retry the operation.
The specified port is being initialized.88906505
WDelete the logical paths on the port and
retry the operation.
Logical paths exist on the port.88916505