Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EPlease contact HP Technical Support.The operation of Add Pair (Paircreate)
or Resume Pair (Pairresync) cannot be
performed, because the data are
remained in the journal cache for the
master journal.
583296505
WCheck the attribute of the specified
journal.
The parameter related to the inflow
cannot be changed, because the
specified journal is a restore journal.
583336505
WCheck the status of the specified journal.The parameter related to the inflow
cannot be changed, because the status
of the specified journal is neither "Initial"
nor "Stopped."
583346505
WCheck the status of the specified journal.The timer type cannot be changed,
because the status of the specified
journal is not "Initial."
583356505
WCheck the CLPR number of the registered
journal volume, and specify the volume
that has the same CLPR number.
The specified volume cannot be
registered as a journal volume because
the CLPR number of the specified volume
is different from the CLPR number of the
journal volume that has already been
registered.
583366505
WCheck the CLPR number of the journal
volume in the specified master journal,
then specify the primary data volume
that has the same CLPR number.
The operation failed, because the CLPR
number of the specified primary data
volume was different from the CLPR
number of the journal volume in the
specified master journal.
583376505
WCheck the CLPR number of the journal
volume in the specified restore journal
group, and specify the secondary data
volume that has the same CLPR number.
The operation failed because the CLPR
number of the specified secondary data
volume was different from the CLPR
number of the journal volume in the
specified restore journal group.
583386505
WCheck the specified volume and specify
a non-LUSE volume.
The specified volume cannot be used as
a journal volume because the specified
volume is an LUSE volume.
583406505
WCheck the specified volume and specify
a non-external volume.
The specified volume cannot be used as
a journal volume because the specified
volume is an external volume.
583416505
WCheck the setting of the volume in the
Data Retention window or the Volume
Retention window.
The specified volume cannot be used as
a journal volume because of a Data
Retention setting or a Volume Retention
setting.
583426505
WCheck the setting of the specified volume
in the Volume Security for Mainframe
window.
The specified volume cannot be used as
a journal volume because of a Volume
Security for Mainframe setting.
583436505
WCheck the specified secondary data
volume and specify a non-LUSE volume.
The Add Pair (Paircreate) operation
failed because the specified secondary
data volume is an LUSE volume.
583446505
182 Message (part code group 6nnn)