Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WBe sure that IO suppression mode of the
specified secondary data volume is
enabled on the Universal Volume Mgr
window. If the IO suppression mode is
disabled, check the microcode version
of DKCMAIN of the secondary storage
system, and contact HP Technical
Support.
The Add Pair (Paircreate) operation
failed due to one of the following
reasons:
The IO suppression mode of the
specified secondary data volume is
enabled.
The microcode version of the
secondary storage system does not
support external volumes.
583456505
WFrom the Data Retention window, check
the settings of the specified secondary
data volume.
The Paircreate operation failed because
a Data Retention VMA was set up on the
specified secondary data volume.
583466505
WCheck the setting of the specified
secondary data volume in the Volume
Security for Mainframe window.
The Add Pair (Paircreate) operation
failed because of a Volume Security for
Mainframe setting on the specified
secondary data volume.
583476505
WFrom the Data Retention window, check
the settings of the specified primary data
volume.
The Paircreate operation failed because
a Data Retention VMA was set up on the
specified primary data volume.
583486505
WFrom the Volume Retention window,
check the settings of the specified
primary data volume.
The Add Pair operation failed because
the specified primary data volume had
a Protect attribute set by Volume
Retention.
583496505
WCheck the status of the primary data
volume in the Business Copy window or
the Business Copy Z window.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was one of the following:
a Business Copy S-VOL
a Business Copy Z T-VOL
a reserved volume
583526505
Part code 6505 183