Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WSpecify the same mirror ID as the
registered mirror ID, then retry the
operation.
A different mirror ID has already been
registered in the specified master journal.
Specify the same mirror ID, because only
one mirror ID can be registered in one
journal.
584586505
WFrom the Compatible FlashCopy
window, check the status of the specified
secondary data volume.
The Add Pair operation or the Resume
Pair operation failed because the
specified secondary data volume was
used by Compatible FlashCopy.
584596505
WConfirm the state of the specified primary
data in the Snapshot window.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was one of the following:
the specified volume was a P-VOL of
Snapshot and was in Reverse Copy
status.
the specified volume was an S-VOL
of Snapshot.
584856505
WCheck the state of the specified primary
data volume.
The Paircreate operation failed because
the specified primary data volume was
a V-VOL for Snapshot.
584866505
WConfirm the status of the specified
primary data volume.
The Paircreate operation failed because
the specified primary data volume was
a Pool-VOL.
584876505
EA communication error between the
primary and the secondary storage
systems occurred, or the microcode of
the secondary storage system does not
support the change pair option function.
Check the main microcode of the
secondary storage system, and contact
HP Technical Support to confirm whether
the microcode supports the change pair
option function. If the microcode supports
the function, contact HP Technical
Support because a communication error
might have occurred.
Only the pair option of the primary data
volume was updated. Failed to update
the pair option of the secondary data
volume.
584906505
WCheck the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
or the Continuous Access Journal Z
function supports external volumes.
The Add Pair (Paircreate) operation
failed because the Continuous Access
Journal or the Continuous Access Journal
Z function of the secondary storage
system does not support external
volumes.
585006505
WCheck the DKCMAIN microcode version
of the secondary storage system, and
contact HP Technical Support to confirm
whether the Continuous Access Journal
function supports Data Retention VMA.
The Paircreate operation failed because
the Continuous Access Journal function
of the secondary storage system does
not support Data Retention VMA.
585016505
WConfirm the licensed capacity of the
Open System Array Management of the
secondary storage system. To perform
the specified operation, purchase a
license key that allows you to use a
capacity larger than the current capacity.
The operation failed because the
capacity of the secondary storage system
has exceeded the licensed capacity of
Open System Array Management.
585026505
Part code 6505 185