EasyManua.ls Logo

HP StorageWorks P9000 - Disk Arrays

HP StorageWorks P9000 - Disk Arrays
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the attribute and the mirror status
of the journal.
The specified operation failed due to the
attribute or the mirror status in the
journal.
585036505
WIf this problem persists, please contact
HP Technical Support.
The operation failed. Please refresh the
window and retry the operation. If this
problem persists, please contact HP
Technical Support.
585046505
WDisable the IO suppression mode of the
specified primary data volume on the
Universal Volume Mgr window.
The Add Pair (Paircreate) operation
failed because the IO suppression mode
of the specified primary data volume was
enabled.
585086505
WCheck the mirror ID assigned to the
specified primary data volume number
(LDKC:CU:LDEV) from the secondary
storage system, and assign a mirror ID
that is not used, and retry the operation.
The Add Pair (Paircreate) operation
failed.
The combination of the specified primary
data volume number (LDKC:CU:LDEV)
and the mirror ID is the same as the
combination specified from another
primary subsystem.
Please check the mirror ID assigned to
the specified primary data volume
number (LDKC:CU:LDEV) from the
secondary subsystem.
In the current microcode version, please
specify a mirror ID different from the ID
used by an existing pair, when you
create a pair by using the same primary
data volume number (LDKC:CU:LDEV).
585106505
WCheck the capacity of the volume, and
specify a volume with larger capacity.
The capacity of the specified volume is
too small.
585306505
WCheck the emulation types of the
specified volumes.
A journal volume cannot be added
because the combination of the
emulation types for the journal volumes
is not correct.
585316505
WCheck the emulation type of the master
and the restore journal.
The Add Pair (Paircreate) operation
failed, because the emulation type is
different between the master journal and
the restore journal.
585326505
WCheck the mirror status of the specified
journal.
The operation to add journal volumes
failed due to the mirror status of the
specified journal.
585506505
WInstall Mainframe Array Management in
the remote storage system or change the
access attribute of the specified primary
data volume to Read/Write.
The operation failed because the license
of the Mainframe Array Management
was not installed in the remote
subsystem.
585526505
WCheck whether the specified volume is
used by Parallel Access Volumes.
The specified volume cannot be used as
a journal volume because it is used by
Parallel Access Volumes.
585536505
EPlease contact HP Technical Support to
install additional shared memory.
A journal volume cannot be added
because the capacity of shared memory
is insufficient.
585606505
186 Message (part code group 6nnn)