Table 53 Error codes (part code 6505) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the timer type of the master and
the restore journal.
The Add Pair operation or the Resume
Pair operation failed, because the timer
type of the master journal was different
from the one of restore journal.
585616505
WRecord the volumes that could not be
blocked.
Clear the Preview list.
Please contact HP Technical Support to
block the volumes.
The specified volumes or the volumes in
the specified journal were deleted.
However, the blockade of the volumes
failed.
Record the volumes that could not be
blocked.
And, clear the Preview list.
Then please contact HP Technical
Support to block the volumes.
585626505
WRetry the operation.
If this problem persists, please contact
HP Technical Support and request to
format the volume.
The specified volume cannot be
registered because the volume has failed
to recover from blockade. Please retry
the operation.
If this problem persists, please contact
HP Technical Support and request to
format the volume.
585636505
WConfirm that the shredding has
completed in the Data Retention window,
then retry the operation.
The Add Pair (Paircreate) operation
failed because the specified primary
data volume was being shredded by
Data Retention. Retry the operation after
the shredding is completed.
585646505
WConfirm that the shredding has
completed in the Data Retention window,
then retry the operation.
The Add Pair (Paircreate) operation
failed because the specified secondary
data volume was being shredded by
Data Retention. Retry the operation after
the shredding is completed.
585656505
WConfirm that the shredding has
completed in the Data Retention window,
then retry the operation.
The specified volume cannot be
registered as a journal volume because
the volume is being shredded by Data
Retention.
Retry the operation after the shredding
is completed.
585666505
WCheck the journal volumes statuses of the
specified master journal.
The operation of Add Pair (Paircreate)
or the Resume Pair (Pairresync) failed,
because the journal volumes of the
specified master journal were blocked.
585906505
WCheck the journal volumes statuses of the
specified restore journal.
The operation of Add Pair (Paircreate)
or the Resume Pair (Pairresync) failed,
because the journal volumes of the
specified restore journal were blocked.
585916505
WCheck the status of the storage system.
Retry the operation after the storage
system has started.
The specified operation failed because
the subsystem was being powered on or
powered off.
585926505