Table 55 Error codes (part code 6510) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the specified controller ID.The specified controller ID cannot be
used.
552026510
WThe value of "Threshold of start Async
JNL" must equal or be less than the
"Threshold of start Sync JNL" value.
Some of the specified values are
incorrect. Two times the value of "M-JNL
Cache" plus the value of "R-JNL Cache"
must be equal to or less than 100. Or,
the value of "Threshold of start Async
JNL" must be equal to or less than the
value of "Threshold of start Sync JNL."
552076510
WSpecify the correct journal number.The specified journal number is incorrect.
Specify the correct journal number.
552086510
WSpecify normal deletion, or specify
"Mirror" as the range.
There are some pairs where "Mirror" is
not specified as the range in the pairs
specified to be deleted forcibly.
Specify "Mirror" as the range when you
want to delete pairs forcibly.
552296510
WTo delete pairs, click [Yes]. Otherwise,
click [No].
[Warning]
There are some pairs where "Group" is
not specified as the range in the pairs
specified to be deleted forcibly.
Other pairs in the same group may
suspend due to a failure by this
operation.
Are you sure you want to delete pairs?
556446510
WRegister a journal that has the same CLPR
number as the specified volume, then
retry the operation.
There is no journal registered that has
the same CLPR number as the specified
volume.
Register a journal that has the same CLPR
number as the specified volume, then
retry the operation.
565046510
WRegister secondary storage systems, then
retry the operation.
There are no secondary subsystems
available. Please register secondary
subsystems and then retry the operation.
565056510
WThere are no consistency groups
available. Create unused consistency
groups, then retry the operation.
There are no consistency groups
available. Please create unused
consistency groups and then retry the
operation.
565226510
WCheck the mirrors of the specified
volume.
No more mirrors can be created for the
specified volume.
565236510
WCheck the error information.An error occurred. Please check the error
details.
590046510
WSpecify the valid value.An invalid value is specified.590056510
WCheck the number of journal volumes in
the specified journal group, or check the
number of the selected volumes.
No more journal volumes can be
registered, or too many volumes are
selected.
590066510
WTo delete the specified storage system,
click [OK]. Otherwise, click [Cancel].
Are you sure you want to delete the
specified subsystems?
590076510
Part code 6510 207

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals