Table 56 Error codes (part code 6610) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WCheck the error information.An error occurred. Please check the error
details.
590046610
WSpecify the valid value.An invalid value is specified.590056610
WCheck the number of journal volumes in
the specified journal group, or check the
number of the selected volumes.
No more journal volumes can be
registered, or too many volumes are
selected.
590066610
WTo delete the specified storage system,
click [OK]. Otherwise, click [Cancel].
Are you sure you want to delete the
specified subsystems?
590076610
WTo delete the specified path, click [OK].
Otherwise, click [Cancel].
Are you sure you want to delete the
paths of the specified subsystem?
590086610
iClick [OK]. Apply the Preview data to
the disk storage system, then retry the
operation.
Since the number of Preview data
exceeded the maximum, the excess data
were discarded. No more Preview data
can be stored.
590096610
iCheck the contents of the primary and
secondary volumes. If the contents match,
click [Yes]. Otherwise, click [No].
WARNING:
Initial copy mode "None" is selected for
some volume pair. Are you sure that the
primary data volume and the secondary
data volume of the pair are already
synchronized?
590106610
iTo output the file, click [Yes]. Otherwise,
click [No].
Are you sure you want to output the %s
file?
590116610
WTo overwrite the file, click [Yes].
Otherwise, click [No].
The specified file already exists. Do you
want to overwrite this file?
590136610
WCheck the DKC setting.The same DKC is specified more than
once. Check the DKC setting.
590266610
WTo continue the operation, click [OK]. To
cancel the operation, click [Cancel].
The current monitoring data will be
deleted if you change the setting of the
monitoring switch. If necessary, use the
Performance Monitor Export Tool to
export the monitoring data file.
The monitoring data saved at present
will be deleted.
590306610
iTo continue processing, click [OK]. To
stop processing, click [Cancel].
The monitoring data currently saved will
be deleted when you change the setting
of the monitoring switch. If necessary,
use the Export Tool to save the
monitoring data.
The monitoring data saved at present
will be deleted when the monitoring
switch is set to Enable the next time.
590316610
WPurchase a license for Continuous Access
Journal Z, then install it.
You cannot add journal volumes because
Continuous Access Journal Z is not
installed.
590406610
Part code 6610 215