Table 62 Error codes (part code 7105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EPlease contact HP Technical Support.An internal logic error occurred.85297105
EPlease contact HP Technical Support.An internal logic error occurred.85307105
EPlease contact HP Technical Support.An internal logic error occurred.85317105
WStop the usage by the host.The command has been rejected,
because the S-VOL or the T-VOL is being
used by the host.
85327105
WSpecify a volume of the supported
emulation type. When the T-VOL is used
as a data volume of Continuous Access
Journal Z, the command cannot be
executed in the current status of
Continuous Access Journal Z pair.
See the section "Sharing Business Copy
Z volumes" in the Business Copy for
Mainframe Systems User Guide for the
relation between the status of Continuous
Access Journal Z pair and the Business
Copy Z operations.
The command has been rejected,
because the emulation type of the
specified volume is not supported or the
specified T-VOL is used as a data volume
of Continuous Access Journal Z.
85337105
EPlease contact HP Technical Support.A processor failure was detected.85357105
EPlease contact HP Technical Support.A cache failure was detected.85367105
EPlease contact HP Technical Support.The cache capacities do not match.85377105
EPlease contact HP Technical Support.An SM failure was detected.85387105
EThere is insufficient shared memory in
DKC. Please contact HP Technical
Support.
There is insufficient shared memory to
create 4096 pairs.
85397105
EPlease contact HP Technical Support.There is sufficient shared memory to
create 4096 pairs, but initial subsystem
setup is required before creating pairs.
85407105
iClose the message box.There is sufficient shared memory to
create 4096 pairs, and the initial
subsystem setup is complete.
85417105
EPlease contact HP Technical Support.Failed to complete the initial shared
memory setup.
85427105
EPlease contact HP Technical Support.The shared memory size is different.85437105
WCheck the contents, and retry.16 Mbytes of shared memory is
available.
85447105
EPlease contact HP Technical Support.A power supply failure is detected.85457105
WRetry the operation with power ON.The command was rejected. The PS OFF
is in progress.
85467105
EPlease contact HP Technical Support.A data transfer failure is detected (CHA).85477105
EPlease contact HP Technical Support.A data transfer failure is detected (DKA).85487105
WYou cannot execute the operation for the
volume which is not implemented.
The S-VOL is not implemented.85497105
Part code 7105 243

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals