Table 62 Error codes (part code 7105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WWithdraw the Compatible FlashCopy
relationship.
The command has been rejected,
because the Compatible FlashCopy
relationship exists.
89917105
EInstall additional shared memory.The command has been rejected,
because sufficient amount of shared
memory is not installed.
89927105
ESet the shared memory extension setting
for Compatible FlashCopy.
The command has been rejected,
because the shared memory is not set
for Compatible FlashCopy.
89937105
WWait a while, and retry the operation.The command has been rejected,
because the disk subsystem is busy.
89947105
WWithdraw the Compatible FlashCopy
relationship.
The command has been rejected,
because the Compatible FlashCopy
relationship exists.
89957105
WWait a while, and retry the operation.The command has been rejected,
because the disk subsystem is busy.
89967105
WUse the Reverse Resync option.Quick Restore cannot be executed
because the specified pair is composed
of the external volumes with different
cache mode settings.
556457105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
563017105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
563027105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
563037105
EPlease contact HP Technical Support.This function cannot be used by the
storage partition administrator.
565247105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing. If this problem persists,
please contact HP Technical Support.
571017105
WSelect a different volume or release the
consistency group setting.
The command has been rejected
because the cascade request for creating
cascade pairs composed of volumes
belonging to the same consistency group
was issued.
580007105
WWait until the L1 pair status changes to
Split, then retry the operation.
The Add Pair command for adding the
L2 pair has been rejected because the
L1 pair is in V-Split status.
580017105
WQuick restore operation cannot be
performed when the pair is composed
of a normal volume and a customized
volume (CV). Select a different pair.
The Quick Restore command has been
rejected because the specified pair is
composed of a normal volume and a
customized volume (CV).
580027105
WTo continue the operation, delete the
remote copy pair.
The command has been rejected
because a remote copy pair exists in the
same subsystem frame.
580037105
250 Message (part code group 7nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals