Table 65 Error codes (part code 8105) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WDelete the external volume that is
mapped to the external port to be
operated, then retry the operation.
An external volume is mapped to the
external port to be operated.
19188105
WCheck the setting.The path cannot be set to the specified
volume, because the volume is being
used as a quorum disk.
19268105
WCheck the setting.The specified volume cannot be set as a
command device, because it is being
used as a quorum disk.
19278105
EUse the SVP to check if the DKC is in the
normal status, then retry. If the same
problem persists despite retrying, please
contact HP Technical Support.
An error occurred during SVP
processing.
20038105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
20058105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
20098105
WRecovery processing may take about 1
minute. Wait for a while.
The LDEV is being used by the host, or
an error occurred in the SVP procedure.
20108105
EPlease contact HP Technical Support.The status of the storage system requires
maintenance (for example, the storage
system is blocked, the shared memory is
inconsistent, or some other factor).
20118105
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
20138105
WIf the same error occurs despite retrying,
please contact HP Technical Support.
An error occurred while connecting to
the storage system.
20158105
EUnmount the host and cancel reservation
of the device. If the host is an AIX host,
unmount the host, and execute the
varyoffvg command.
Processing is disabled because the host
is mounted or the device is reserved.
20828105
WCheck the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
The subsystem status is invalid.20838105
WCheck the DKC status and the current
status of the configuration setting. If
necessary, re-execute the setting
operation.
The subsystem status is invalid.20848105
WCheck the settings, then retry the
operation.
The host specified by the WWN is
performing I/O operations.
20978105
WDelete or suspend all pairs to which the
journal volumes belong.
Devices to be maintained include journal
volumes.
22048105
WDelete all pairs to which the journal
volumes belong.
Devices to be maintained include journal
volumes.
22058105
WRelease the reserved attribute of the
target volume by using Data Retention.
No settings can be made because of a
volume reserved for RAID Manager.
25048105
264 Message (part code group 8nnn)