Table 21 Error codes (part code 0605) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
WClear the duplicated setting, then retry
the operation.
The External Path Group specified as a
migration source has already been used
as a migration target.
657960605
WClear the duplicated setting, then retry
the operation.
The External Path Group specified as a
migration target has already been used
as a migration source.
657970605
WCheck the specified External Path Group.The path configuration of the External
Path Group between the migration
source and the migration target is
different.
657980605
WCheck the contents of the spreadsheet.There are no setting lines of
NewPathGroup.
657990605
WCheck the contents of the spreadsheet.The number of NewPathGroup setting
lines exceeds the limit.
658000605
WCheck the setting of ExG.There are no setting lines of the ExG.658010605
WCheck the contents of the spreadsheet.There are no setting lines of
TargetPathGroup.
658020605
WDelete unnecessary external LU(s), then
retry the operation.
The number of external LUs that can be
connected from a single port has
exceeded the maximum value.
660110605
WOperate within the ports of the
connected external storage system.
The number of registered ports of the
external storage system has exceeded
the maximum.
660120605
WChange the emulation type to be set in
the volume.
The specified emulation type cannot be
set because 3390-3R is set in the storage
system.
660130605
WChange the emulation type to be set in
the volume.
The specified emulation type cannot be
set because 3390-3 is set in the storage
system.
660140605
WCheck the number of LDEVs.The number of LDEVs that can be defined
in an external volume has exceeded the
maximum value.
665010605
WCheck the setting of ExG.Specified ExG has already been used.665020605
WCheck the setting of LDKC, CU, and
LDEV.
LDKC, CU, and LDEV are not set within
the range where they can be used.
665030605
WCheck the setting of LDKC, CU, and
LDEV.
Specified LDKC:CU:LDEV has already
been used.
665040605
WCheck the setting of emulation groups
within the range grouped by 32LDEV
numbers.
The specified LDEV number has already
been assigned to another emulation
group within the range grouped by 32
LDEV numbers.
665050605
WCheck the setting of SSID.Specified SSID has already been used.665060605
WCheck the status and the capacity of
target external volume.
The target external volume is blocked or
not set within the range of capacity that
can be used.
665070605
WCheck the setting of LDEV capacity.The specified LDEV capacity is invalid.665080605
Part code 0605 45

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals