Table 31 Error codes (part code 3005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EIf this problem persists, please contact
HP Technical Support.
An error occurred while connecting to
the subsystem.
585753005
EIf this problem persists, please contact
HP Technical Support.
A communication time-out error
occurred in the disk subsystem.
585763005
WResynchronize the pair or release the
pair definition, then retry the operation.
The specified operation cannot be
performed, because the Snapshot pair
using the pool volumes to be
maintained is in PSUS status or being
restored.
586233005
WCancel the pair definition, then retry the
operation.
A Snapshot pair is defined.586263005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
587063005
WCheck the setting of the specified volume.The specified volume is used as a
System Disk volume.
656503005
WCheck the setting of the specified volume.The specified volume is used as a Thin
Provisioning volume.
656593005
WRelease the association between the pool
volume and the Thin Provisioning volume.
The pool volumes associated with the
Thin Provisioning volume is included in
the items to be maintained.
656713005
WCheck the setting and status of the LDEV
in the specified parity group.
The LDEV to be operated is not included
in the specified parity group.
656753005
WConfirm that it is associated with a pool
in the same CLPR.
The association cannot be made
because the pool is in a different CLPR.
656763005
WCancel the format processing from the
SVP, then retry the formatting processing
again.
A failure occurred while formatting.656883005
WCancel the quick formatting processing
from the SVP, then execute the quick
formatting processing again.
A failure occurred while quick
formatting.
656893005
WCheck the settings and retry the
operation.
The specified volumes contain volumes
that are being quick formatted.
656903005
WCheck the status and wait until the status
changes to a status that maintenance is
possible.
Preparing for quick format.656913005
WSelect only the volumes that quick format
can be executed and execute quick
format.
The specified volumes contain volumes
that quick format cannot be executed.
656923005
WAdd the System Disk, or restore the
blocked System Disk then retry Quick
Format.
If this problem persists even though the
system disk is normal and has enough
capacity, please contact HP Technical
Support.
Quick Format cannot be executed.
There is no System Disk area for Quick
Format, the capacity of the System Disk
is insufficient, or the System Disk is
blocked.
656933005
WChange the setting or execute the quick
formatting process after the quick format
processing for other parity groups has
completed.
Quick format cannot be executed
because the number of parity groups
being quick formatted has exceeded
the maximum.
656943005
82 Message (part code group 3nnn)

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals