Table 31 Error codes (part code 3005) (continued)
Severity
Level
Recommended ActionError MessageError
Number
Part
Code
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
656953005
WSelect only the volumes that can be
formatted and format the volumes.
The specified volumes contain volumes
that cannot be formatted.
657173005
WCheck if the configuration changing
process by RAID Manager, Auto LUN,
or Quick Restore is not in the operation,
then retry the operation.
The configuration changing processes
are conflicting at DKC.
657403005
WCheck the specified volume.The specified volume contains a quorum
disk.
657673005
WCheck the specified volume.The specified volume includes a remote
command device being used by a
mirror of the journal group.
657903005
WCheck the setting of the specified volume.The specified volume is not a Thin
Provisioning volume.
687223005
EPlease contact HP Technical Support.An internal logic contradiction occurred
on the DKC side.
687233005
WInstall the shared memory.Shared memory is not installed.687243005
WDelete the unnecessary Thin Provisioning
Pool (THP Pool) and Thin Provisioning
volume (V-VOL), then retry the operation.
If this problem persists, please contact
HP Technical Support.
The shared memory for the V-VOL
management area is insufficient.
687253005
WCheck volume capacity for the V-VOL.The capacity of Thin Provisioning
volume (V-VOL) is insufficient.
687263005
WWait a while, then retry the operation.Shared memory is being initialized.687273005
WRecover the pool, then retry the
operation.
The pool is in an abnormal state.687283005
WRetry the operation after the formatting
operation has completed.
LDEV format is being executed in the
specified volume.
687293005
EIf this problem persists, please contact
HP Technical Support.
An error occurred during SVP
processing.
687363005
WCheck the current configuration of
association.
The number of Thin Provisioning
volumes that can be associated with a
single pool has exceeded the
maximum.
687483005
WWait for a while, then retry the
operation.
The disk storage system is executing the
processing to release the association,
inside.
687513005
EIf this problem persists, please contact
HP Technical Support.
An error occurred on the DKC side.687613005
WCheck the specified parity group.The specified parity group is not
mounted.
687853005
WCheck the status of the specified parity
group.
The specified parity group is not
blocked.
687863005
Part code 3005 83

Table of Contents

Other manuals for HP StorageWorks P9000 - Disk Arrays

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks P9000 - Disk Arrays and is the answer not in the manual?

HP StorageWorks P9000 - Disk Arrays Specifications

General IconGeneral
BrandHP
ModelStorageWorks P9000 - Disk Arrays
CategoryStorage
LanguageEnglish

Related product manuals