3. Save your setting.
Setting the automatic power-on state
Use the Automatic Power-On option to configure how the server automatically powers on when AC
power is applied. By default, the system returns to its previous power state when AC power is restored
after an AC power loss.
Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > System Options > Server Availability > Automatic Power-On.
2. Select a setting.
Always Power On—The system automatically returns to a power on state, even if it was in the “off”
state when power was lost.
Always Power Off—The system automatically returns to a power off state.
Restore Last Power State—The system automatically returns to its previous power off state.
3. Save your setting.
Setting the power-on delay
Use the Power-On Delay option to set whether to delay the server from turning on for a specified time.
This option enables staggering when the server powers up after a power loss, which can prevent power
usage spikes.
NOTE: These events override the Power-On Delay setting and immediately power on the server:
Pressing the power button using the iLO Virtual Power Button
Wake-ON LAN events
RTC (Real-Time Clock) wake-up events
Procedure
1. From the System Utilities screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > System Options > Server Availability > Power-On Delay.
2. Select a setting.
No Delay
Random Delay
15 Second Delay
60 Setting the automatic power-on state