PCI BUS—The PCI bus to which the iLO processer is attached.
Device—The device number assigned to iLO in the PCI bus.
Viewing information about iLO
Procedure
1. From the System Utilities screen, select System Configuration > iLO 5 Configuration Utility >
About.
2. View information about iLO components.
Viewing and configuring embedded device information
Viewing controller information
Procedure
1. From the System Utilities screen, select System Configuration > controller > Controller
Information.
2. In the Controller Information screen, view the information.
Configuring controller settings
Modifying controller settings
Procedure
1. From the System Utilities screen, select System Configuration > controller > Configure Controller
Settings > Modify Controller Settings.
2. In the Modify Controller Settings screen, modify any of the following settings:
Setting Description
Cache Ratio (Read) Adjusts the amount of memory for
read-ahead cache versus write cache.
Range is from 0-100; value can be
increased or decreased in increments
of 5.
Configured Physical Drive
Write Cache State
Enables or disables the setting for the
write cache on all configured physical
drives.
Options are Enabled, Disabled or
Default.