CAUTION:CAUTION:
Before replacing a DIMM, backplane, expansion card, riser board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot.
When installing the replacement component:
Observe antistatic precautions.
Handle the PCA only along the edges.
Do not touch the components and connectors on the PCA.
Do not bend or flex the PCA.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel.
7. Disconnect the boot device signal and power cables from the system board .
8. Remove the boot device from the top of the power supply cage:
a. Pull and hold the latch (callout 1).
b. Remove the boot device from the chassis side wall (callout 2).
HPE ProLiant ML350 Gen11 Server Maintenance and Service Guide 141