To replace the component, reverse the removal procedure.
When installing the fan replacement, make sure that the fan clicks into place.
Removing and replacing the internal fan in non-hot-plug modeRemoving and replacing the internal fan in non-hot-plug mode
About this taskAbout this task
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel.
7. Remove the internal fan:
a. Press and hold the latch (callout 1).
b. Lift the fan from the bay (callout 2).