Remove the server from the rack .
6. Remove the access panel.
7. Remove the chassis intrusion detection switch:
a. Disconnect the switch cable and release it from the cable clamp (callout 1).
b. While carefully retracting the snap-in latch (callout 2), pull out the tab from the chassis slot (callout 3).
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the OCP NIC 3.0 adapterRemoving and replacing the OCP NIC 3.0 adapter
About this taskAbout this task
CAUTION:CAUTION:
Before replacing a DIMM, backplane, expansion card, riser board, or other similar PCA components due to a perceived
hardware error, make sure first that the component is firmly seated in the slot.
When installing the replacement component:
Observe antistatic precautions.
Handle the PCA only along the edges.
Do not touch the components and connectors on the PCA.
Do not bend or flex the PCA.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.