a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
If the server is in rack mode, remove the server from the rack .
5. Remove the access panel.
6. Remove the secondary riser cage blank.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the tertiary riser slot coverRemoving and replacing the tertiary riser slot cover
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a spudger or any small prying tool available.
About this taskAbout this task
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
HPE ProLiant ML350 Gen11 Server Maintenance and Service Guide 153