2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel.
7. If installed, remove the boot device.
8. Disconnect the energy pack extension cable from the system board.
9. Remove the energy pack:
a. Press and hold the release latch (callout 1).
b. Lift one end of the energy pack and release it from the holder (callouts 2 and 3).
10. Disconnect the energy pack extension cable from the energy pack cable.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the energy pack holderRemoving and replacing the energy pack holder
ProcedureProcedure
1. Power down the server.