SpecificationsSpecifications
SubtopicsSubtopics
Environmental specificationsEnvironmental specifications
Limited operating inlet ambient temperature requirementsLimited operating inlet ambient temperature requirements
Mechanical specificationsMechanical specifications
Power supply specificationsPower supply specifications
Environmental specificationsEnvironmental specifications
SpecificationsSpecifications ValueValue
Temperature range*Temperature range* —
Operating 10°C to 35°C (50°F to 95°F)
Nonoperating -30°C to 60°C (-22°F to 140°F)
Relative humidity (noncondensing)Relative humidity (noncondensing) —
Operating 8% to 90%
28°C (82.4°F) maximum wet bulb temperature, noncondensing
Nonoperating 5% to 95%
38.7°C (101.7°F) maximum wet bulb temperature, noncondensing
AltitudeAltitude —
Operating 3050 m (10,000 ft)
This value may be limited by the type and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1,500 ft/min).
Nonoperating 9144 m (30,000 ft)
Maximum allowable altitude change rate is 457 m/min (1,500 ft/min).
Standard operating supportStandard operating support
10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1,000 ft) above sea level to a