a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the external fan connector blank.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the chassis intrusion detection switchRemoving and replacing the chassis intrusion detection switch
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .