a. Remove the cable screw (callout 1).
b. Remove the cable from the cable connector slot (callout 2).
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the fan blankRemoving and replacing the fan blank
About this taskAbout this task
CAUTION:CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with
either a component or a blank.
ProcedureProcedure
1. Power down the server.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. If the server is in tower mode, place the server on a flat, level surface with the access panel facing up .
5. If the server is in rack mode, do one of the following:
Extend the server from the rack .
Remove the server from the rack .
6. Remove the access panel.
7. Remove the fan blank.
HPE ProLiant ML350 Gen11 Server Maintenance and Service Guide 85