ItemItem DescriptionDescription StatusStatus DefinitionDefinition
1 Power supply Solid green The power supply is operating normally.
Off One or more of the following conditions exists:
Power is unavailable
Power supply failure
Power supply is in standby mode
Power supply error
2 iLO status Solid green Linked to network
Flashing green Network active
Off No network activity
3 iLO link Solid green Network link
Off No network link
4 UID Solid blue Activated
Flashing blue
1 flash per second—Remote management or firmware
upgrade in progress
4 flashes per sec—iLO manual reboot sequence initiated
8 flashes per sec—iLO manual reboot sequence in progress
Off Deactivated