Shenzhen Hpmont Technology Co., Ltd. Chapter 6 Function Introduction
HD5L-PLUS Series User Manual V1.0 73
6.2.20 F19: Enhance Parameters
Ref. Code Function Description Setting Range [Default]
F19.43
Optimize 1313 encoder CD signal
0,1 [0]
0: Not optimized.
1: Optimize.
F19.44
SVC5 control selection
0,1 [0]
0: Normal processing.
1: Optimized processing.
F19.45
Hardware circuit detection method
0,1 [0]
0: Sample 1.
1: Sample 2.
F19.46
SVC flux cutoff frequency
0.30 - 3.00 [0.50Hz]
F19.47
SVC velocity estimation filter coefficients
0 - 2 [0]
0: 8.
1: 16.
2: 32.
F19.48 SVC velocity observation period 0,1 [0]
0: 1ms.
1: Interrupt.
F19.49 SVC no-load current boost 0,1 [0]
0: Boost.
1: Not boost.
F19.50
SVC5/SVC6 low-speed variable carrier enable
0,1 [0]
0: Unable.
1: Enable.
F19.51
Motor overload protection percentage
150 - 200 [170%]
F19.52
Motor overload protection time
0 – 10 [5s]
0 - 3: Not work.
4 - 10: Protect.
F19.53 Modify the no-load current to automatically update the mutual
inductance value
0,1 [0]
0: Auto change.
1: Do not change automatically.
F19.54
Maintenance operation command to remove the processing method
0,1 [0]
0: Downtime processing.
1: Switch to multi-speed operation.
F19.55
Electric and power generation slip compensation gain compensation
enable respectively
0,1 [0]
0: Unable.
1: Enable.
F19.56
Electric slip compensation gain
20.0 - 200.0 [100.0%]
F19.57
Power generation slip compensation gain
20.0 - 200.0 [100.0%]
6