Table 5-5 DIMM conguration rules
CPU DIMM Installation Sequence
Each CPU J1, J4, J7, J10, J2, J5, J8, and J11
Prerequisites
Conditions
You have removed the memory board from the RH8100 V3. For details, see 5.2.3
Removing a Memory Board.
Data
You have obtained the cabinet number and chassis number of the RH8100 V3.
You have located the RH8100 V3 based on the preceding information, and
labeled its panel to prevent misoperations.
You have determined the position on the RH8100 V3 for installing a DIMM.
Tools
ESD gloves
Packaging materials, for example, an ESD bag
Hardware
Spare DIMM
Procedure
Step 1 Wear an ESD wrist strap or ESD gloves. For details, see 1 Safety Instructions.
Step 2 Take the spare DIMM out of its ESD bag.
Step 3 Open the two
xing clips of the DIMM slot. See Figure 5-17.
Figure 5-17 Opening the xing clips of a DIMM slot
Step 4 Align the DIMM with the DIMM slot, and insert the DIMM into the slot. See
Figure 5-18.
The two xing clips close automatically.
RH8100 V3 Server
User Guide 5 Removing and Installing Parts of the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 129