Parameter Description
RAID Mode Congures the RAID mode as single-RAID or dual-RAID.
If the FM-B, FM-C, or FM-D is installed on the
RH8100 V3, RAID Mode is unavailable.
If the RH8100 V3 is in single-system, RAID Mode
is unavailable regardless of the RAID controller
card quantity.
In dual-system, system A uses RAID-1 and system
B uses RAID-2.
If the FM-A is installed on the RH8100 V3 and the
server is in single-system, you can
congure the RAID
mode as single-RAID or dual-RAID.
In single-RAID mode, only RAID-1 can be used.
In dual-RAID mode, both RAID-1 and RAID-2 can
be used.
The dual-RAID mode is recommended if the FM-A is
installed on the RH8100 V3 and the server is in dual-
system mode.
In single-RAID mode, system B has no hard disk.
Therefore, you are advised to switch the RAID
mode from single-RAID to dual-RAID by using the
iBMC of system A. In dual-RAID mode, system A
uses RAID-1 and system B uses RAID-2.
Do not switch the RAID mode from dual-RAID to
single-RAID.
Do not use the iBMC of system B to
congure the
RAID mode.
If you want to select Dual RAID, ensure that the
RH8100 V3 has two RAID controller cards. Before you
switch the RAID mode between single-RAID and dual-
RAID, ensure that the OS is powered on.
If you want to select Single RAID, ensure that a
compute module with CPUs is installed in slot 1. If you
want to select Dual RAID, ensure that compute
modules with CPUs are installed in slots 1 and 5.
Value: Single RAID or Dual RAID
Setting method: Click an option button.
7. In the RAID Mode area, select Dual RAID, as shown in Figure 7-35.
Figure 7-35 RAID Mode area
RH8100 V3 Server
User Guide 7 Conguring the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 345

Table of Contents