EasyManua.ls Logo

IAI X-SEL - Page 234

IAI X-SEL
535 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
204
INTELLIGENT ACTUATOR
Part 4 Commands
BASE (Specify axis base)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional BASE
Axis
number
Prohibited CP
[Function] Count the axes sequentially based on the axis number specified in operand 1 being the first
axis.
A BASE command can be used with PRED, PRDQ, AXST, actuator-control, ARCH, PACH,
PMVP, PMVL and zone commands. Note that each zone range is assigned to the actuator
via parameter.
[Example 1] HOME 1 Axis 1 returns to the home.
BASE 2 Axis 2 is considered the first axis.
HOME 1 Axis 2 returns to the home.
Hereafter, axes 2 to 4 will operate based on the specifications for axes 1 to 3 (axis number,
axis pattern, position data, etc.).
[Example 2] LET 1 3 Assign 3 to variable 1.
BASE *1 The content of variable 1 (axis 3) will be considered as the
first axis.
Hereafter, axes 3 and 4 will operate based on the specifications for axes 1 and 2.

Table of Contents

Other manuals for IAI X-SEL