EasyManua.ls Logo

IAI X-SEL

IAI X-SEL
535 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
264
INTELLIGENT ACTUATOR
Part 4 Commands
VAL (Convert character string data; decimal)
Command, declaration
Extension condition
(LD, A, O, AB, OB)
Input condition
(I/O, flag)
Command,
declaration
Operand 1 Operand 2
Output
(Output, flag)
Optional Optional VAL
Variable
number
Column
number,
character literal
CC
[Function] Convert the decimal data in the column specified in operand 2 to a binary and assign the
result to the variable specified in operand 1.
Conversion will be performed for the length set by a SLEN command.
If a character-string literal is specified in operand 2, conversion will be performed for the
entire length of the literal.
(Note) Keep the converting length to 18 characters or less.
[Example] SCPY 10 ‘1234’ Set ‘1234’ in column 10.
SLEN 4 Set the converting length to four bytes.
VAL 1 10 Assign 1234, which is a binary converted from ‘1234’ in
column 10, to variable 1.
LET 1 100 Assign 100 to variable 1.
LET 2 20 Assign 20 to variable 2.
SCPY 20 ‘1234’ Copy ‘1234’ to column 20.
SCPY 24 ‘.567’ Copy ‘.567’ to column 24.
SLEN 8 Set the converting length to eight bytes.
VAL *1 *2 Assign 1234.567, which is a binary converted from
‘1234.567’ in the content of variable 2 (column 20) to the
content of variable 1 (variable 100).