582 Implementing the IBM Storwize V5000 Gen2 with IBM Spectrum Virtualize V8.1
If the relationship or Consistency Group becomes disconnected, the auxiliary side transitions
to InconsistentDisconnected. The master side transitions to IdlingDisconnected.
InconsistentCopying
InconsistentCopying is a connected state. In this state, the master is accessible for read and
write I/O, but the auxiliary is not accessible for read or write I/O. This state is entered after a
start command is issued to an InconsistentStopped relationship or a Consistency Group.
It is also entered when a forced start is issued to an Idling or ConsistentStopped relationship
or Consistency Group. In this state, a background copy process runs that copies data from
the master to the auxiliary volume.
In the absence of errors, an InconsistentCopying relationship is active, and the copy
progress increases until the copy process completes. In certain error situations, the copy
progress might halt or even regress.
A persistent error or stop command places the relationship or Consistency Group into an
InconsistentStopped state. A start command is accepted but has no effect.
If the background copy process completes on a stand-alone relationship or on all
relationships for a Consistency Group, the relationship or Consistency Group transitions to
the ConsistentSynchronized state.
If the relationship or Consistency Group becomes disconnected, the auxiliary side transitions
to InconsistentDisconnected. The master side transitions to IdlingDisconnected.
ConsistentStopped
ConsistentStopped is a connected state. In this state, the auxiliary contains a consistent
image, but it might be out-of-date in relation to the master. This state can arise when a
relationship was in a ConsistentSynchronized state and experienced an error that forces a
Consistency Freeze. It can also arise when a relationship is created with a
CreateConsistentFlag set to TRUE.
Normally, write activity that follows an I/O error causes updates to the master, and the
auxiliary is no longer synchronized. In this case, consistency must be given up for a period to
reestablish synchronization. You must use a start command with the -force option to
acknowledge this condition, and the relationship or Consistency Group transitions to
InconsistentCopying. Enter this command only after all outstanding events are repaired.
In the unusual case where the master and the auxiliary are still synchronized (perhaps
following a user stop, and no further write I/O was received), a start command takes the
relationship to ConsistentSynchronized. No -force option is required. Also, in this case, you
can enter a switch command that moves the relationship or Consistency Group to
ConsistentSynchronized and reverses the roles of the master and the auxiliary.
If the relationship or Consistency Group becomes disconnected, the auxiliary transitions to
ConsistentDisconnected. The master transitions to IdlingDisconnected.
An informational status log is generated whenever a relationship or Consistency Group enters
the ConsistentStopped state with a status of Online. You can configure this event to generate
an SNMP trap that can be used to trigger automation or manual intervention to issue a start
command following a loss of synchronization.

Table of Contents

Other manuals for IBM Storwize V5030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V5030 and is the answer not in the manual?

IBM Storwize V5030 Specifications

General IconGeneral
ModelIBM Storwize V5030
CategoryStorage
Controller Enclosures1 or 2
Maximum Drives240
RAID Levels0, 1, 5, 6, 10
VirtualizationYes
Data CompressionYes
Maximum Hosts512
Form Factor2U
Drive TypesSAS, NL-SAS, SSD
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 12 Gb SAS
Processor Cores8 per controller