680 Implementing the IBM Storwize V5000 Gen2 with IBM Spectrum Virtualize V8.1
12.2.5 Power supply units
All enclosures require two power supply units (PSUs) for normal operation. A single PSU can
power the entire enclosure for redundancy. We advise that you supply AC power to each PSU
from different power distribution units (PDUs).
Figure 12-22 shows a fully equipped control enclosure with two supply units. The PSUs are
identical between the control and expansion enclosures.
Figure 12-22 Power supply units
The left PSU is numbered 1, and the right PSU is numbered 2.
Power supplies in both control and expansion enclosures are hot-swappable and replaceable
without a need to shut down a node or cluster. If the power is interrupted in one node canister
for less than 2.5 seconds, the canister cannot perform a fire hose dump and continues
operation from battery.

Table of Contents

Other manuals for IBM Storwize V5030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V5030 and is the answer not in the manual?

IBM Storwize V5030 Specifications

General IconGeneral
ModelIBM Storwize V5030
CategoryStorage
Controller Enclosures1 or 2
Maximum Drives240
RAID Levels0, 1, 5, 6, 10
VirtualizationYes
Data CompressionYes
Maximum Hosts512
Form Factor2U
Drive TypesSAS, NL-SAS, SSD
Host Interface8 Gb FC, 16 Gb FC, 10 Gb iSCSI, 12 Gb SAS
Processor Cores8 per controller

Related product manuals