EasyManuals Logo
Home>IBM>Storage>Storwize V5030

IBM Storwize V5030 User Manual

IBM Storwize V5030
864 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #657 background imageLoading...
Page #657 background image
Chapter 10. Copy services 635
10.12.2 Failure scenarios
If one node fails, the other node in the same I/O group takes over the responsibility for all
volumes that are owned by the affected I/O group, as shown in Figure 10-161. The system
can deactivate the write cache, which might influence the overall performance. The multipath
driver can switch the active paths to the named node. The Metro Mirror relationship continues
to operate and provides a synchronous, consistent copy at the remote I/O group.
Figure 10-161 Single node failure in an I/O group

Table of Contents

Other manuals for IBM Storwize V5030

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM Storwize V5030 and is the answer not in the manual?

IBM Storwize V5030 Specifications

General IconGeneral
BrandIBM
ModelStorwize V5030
CategoryStorage
LanguageEnglish

Related product manuals