Auto Sentry® flex User Manual 42 Introduction
The Deterrent Break-in Alarm settings are configured in WashConnect through the System Setup/
Devices/Settings/TouchConfiguration/Vandalism Deterrent Settings: Deterrent Break-In Alarm
Output 1 and 2.
In order to install the Electronic Vibration Detector, WashConnect needs to be on version 1.4.5.1 or
later. Contact ICS technical support to see if you can update WashConnect and install the
Electronic Vibration Detector.
In addition to the video, and up to two fired outputs, you can configure the system to send a
Critical email Alert via WashConnect. The email would post an Event Code of 2001e when the
alarm is triggered. The received Critical alert email message reads: VANDALISM ALARM IS ON –
NEEDS IMMEDIATE ATTENTION.
Vandalism Sensor
Guard your Auto Sentry with the Vandalism Sensor. The Seismic Detector needs to be installed
inside the top of the Auto Sentry. The Seismic Detector is wired to the SIO or PIO board. When the
Seismic detector senses tampering of the unit, the VandalismAlarm.avi video plays on the Auto
Sentry screen. This is known as the Break-In alarm.
The Seismic detector will also fire up to two outputs. The outputs may control lights, horns, or may
provide a signal to the alarm company’s monitoring system to notify authorities of the warning.
The Vandalism Warning parameters are configured in WashConnect through the System Setup/
Devices/Settings/TouchConfiguration/Vandalism Deterrent settings: Deterrent Break-In Alarm
Output 1 and 2.
Table 2: Auto Sentry Vandalism Deterrent
Field Description
Deterrent Alarm Output Numeric. The output that will be fired when the alarm is tripped.
Deterrent Alarm Time Out Numeric. Minutes. If set to zero, the alarm never resets based on this
timeout. Any number entry greater than zero represents the time to
wait (in minutes) until the alarm is automatically reset.
Deterrent Disarm Alarm Time Out Numeric. Seconds. How long the alarm stays off after you press the
Disable Alarm button in the Service Unit diagnostics screen.
Deterrent Enable True or False. Enable or disable the vandalism alarm.
Deterrent On Change Low High Type HIGH if the alarm triggers on a logic change from low to high.
Else, type LOW.