Parameter List
‑11‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
F1‑04 0xF104 Rated motor
frequency
0.01 Hz to F0‑10 50 Hz At stop "
F1‑04
"
on
page 107
F1‑05 0xF105 Rated motor
speed
1–65535 RPM 1460 RPM At stop "
F1‑05
"
on
page 108
F1‑06 0xF106 Asynchronous/
Synchronous
motor stator
resistance
0.001 Ω to 65.535 Ω 1.204 Ω At stop "
F1‑06
"
on
page 108
F1‑07 0xF107 Asynchronous
motor rotor
resistance
0.001 Ω to 65.535 Ω 0.908 Ω At stop "
F1‑07
"
on
page 108
F1‑08 0xF108 Asynchronous
motor leakage
inductance
0.01 mH to 655.35 mH 5.28 mH At stop "
F1‑08
"
on
page 108
F1‑09 0xF109 Asynchronous
motor mutual
inductance
0.1 mH to 6553.5 mH 156.8 mH At stop "
F1‑09
"
on
page 109
F1‑10 0xF10A Asynchronous
motor no‑load
current
0.1 A to F1‑03 4.2 A At stop "
F1‑10
"
on
page 109
F1‑11 0xF10B Asynchronous
motor core
saturation
coefficient 1
50.0% to 100.0% 86 % In real time "
F1‑11
"
on
page 109
F1‑12 0xF10C Asynchronous
motor core
saturation
coefficient 2
100.0% to 150.0% 130 % In real time "
F1‑12
"
on
page 110
F1‑13 0xF10D Asynchronous
motor core
saturation
coefficient 3
100.0% to 170.0% 140 % In real time "
F1‑13
"
on
page 110
F1‑14 0xF10E Asynchronous
motor core
saturation
coefficient 4
100.0% to 180.0% 150 % In real time "
F1‑14
"
on
page 110
F1‑17 0xF111 Synchronous
motor axis D
inductance
0.01 mH to 655.35 mH 15.86 mH At stop "
F1‑17
"
on
page 110
F1‑18 0xF112 Synchronous
motor axis Q
inductance
0.01 mH to 655.35 mH 15.86 mH At stop "
F1‑18
"
on
page 111
F1‑19 0xF113 Synchronous
motor back EMF
coefficient
0.0 V to 6553.5 V 0 V At stop "
F1‑19
"
on
page 111
F1‑20 0xF114 Filter time
constant (PMVVC)
0.003–65.535 0.1 ‑ In real time "
F1‑20
"
on
page 111