Parameter List
‑79‑
Parame
ter
Address Name Value Range Default Unit Change
Method
Page
B0‑27 0xB01B Tension frequency
limit offset
0.00 Hz to 100.00 Hz 5 Hz In real time "
B0‑27
"
on
page 418
B0‑28 0xB01C Tension frequency
limit
0: Disabled
1: Enabled
0 ‑ In real time "
B0‑28
"
on
page 418
B0‑29 0xB01D Pulses per
revolution
1–60000 1 ‑ In real time "
B0‑29
"
on
page 419
B0‑30 0xB01E Revolutions per
layer
1 to 10000 1 ‑ In real time "
B0‑30
"
on
page 419
B0‑31 0xB01F Material thickness
reference source
0: Digit setting
1: AI1 setting
2: AI2 setting
3: AI3
0 ‑ At stop "
B0‑31
"
on
page 420
B0‑32 0xB020 Material thickness
0
0.01–100.00 mm 0.01 mm In real time "
B0‑32
"
on
page 420
B0‑33 0xB021 Material thickness
1
0.01–100.00 mm 0.01 mm In real time "
B0‑33
"
on
page 420
B0‑34 0xB022 Material thickness
2
0.01–100.00 mm 0.01 mm In real time "
B0‑34
"
on
page 421
B0‑35 0xB023 Material thickness
3
0.01–100.00 mm 0.01 mm In real time "
B0‑35
"
on
page 421
B0‑36 0xB024 Maximum
thickness
0.01 mm to 100.00 mm 1 mm In real time "
B0‑36
"
on
page 421
B0‑37 0xB025 Winding diameter
not reset upon
stop
0: Disabled
1: Enabled
0 ‑ In real time "
B0‑37
"
on
page 421
B0‑38 0xB026 Closed‑loop
tension torque
mode selection
0: Torque calculated through
PID only
1: Torque calculated through
main + PID
0 ‑ At stop "
B0‑38
"
on
page 422
B0‑40 0xB028 Minimum pre‑drive
torque limit
0.0% to 100.0% 0 % In real time "
B0‑40
"
on
page 422
B0‑41 0xB029 Constant linear
speed source
selection
0: AI1
1: AI2
2: AI3
3: Pulse setting (DI5)
Communication setting
(1000H)
5: Communication setting
(731AH)
0 ‑ At stop "
B0‑41
"
on
page 422
B1‑00 0xB100 Tension reference
source
0: B0‑01 setting
1: AI1 setting
2: AI2 setting
3: AI3 setting
4: Pulse setting (DI5)
5: Communication setting
(1000H)
0 ‑ At stop "
B1‑00
"
on