A-17 Appendix A Alert and Maintenance INFO List
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
APP A
23
24
25
Message Explanation Advice
Anemometer(Communic
ation failed, Main LAN)
Communication with
Anemometer cannot be
performed via Main LAN.
Check the condition of Anemometer and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Anemometer(Communic
ation failed, Sub LAN)
Communication with
Anemometer cannot be
performed via Sub LAN.
Check the condition of Anemometer and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor.
Autopilot(Communicatio
n Failed, Main LAN)
Communication with
Autopilot cannot be
performed via Main LAN.
"Check the condition of Autopilot and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Autopilot(Communicatio
n Failed, Sub LAN)
Communication with
Autopilot cannot be
performed via Sub LAN.
"Check the condition of Autopilot and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Azimuth Thruster
#n(invalid)
There is a format error or
a status error of the data.
Check the sensor condition.
Azimuth Thruster #n(not
plausible)
There is a range error of
the data.
Check the sensor condition.
Azimuth Thruster
#n(unavailable)
The data cannot be
received.
Check the condition of the sensor and the
communication path.
BNWAS(Communication
failed, Main LAN)
Communication with
BNWAS cannot be
performed via Main LAN.
"Check the condition of BNWAS and Main
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
BNWAS(Communication
failed, Sub LAN)
Communication with
BNWAS cannot be
performed via Sub LAN.
"Check the condition of BNWAS and Sub
LAN.
If it cannot be recovered after you check the
connection of the equipment cable in
power-off status and restart, turn off the
power of the device and contact your
distributor."
Bow Azimuth Thruster
#n (invalid)
There is a format error or
a status error of the data.
Check the sensor condition.