6-21  Section 6 Target Tracking and AIS 
 
 
 
 
 
 
6.5.2.2  Using the cursor 
1 
Select AZ ([Use AZ1] or [Use AZ2]) to be set. 
2  Click on the starting azimuth position.   
The starting azimuth is set.   
3  Move the cursor and click on the ending azimuth position.   
A line connecting the starting azimuth and the ending azimuth is displayed.   
4  Move the cursor and click at the start distance position. 
An arc appears at the start distance position. 
5  Move the cursor and click at the end distance position. 
This creates an automatic acquisition/activation zone (AZ) of fan shape that is enclosed by the 
starting azimuth, the ending azimuth, and the ending distance.   
 
 
6.5.2.3  Using the EBL/VRM dial for the setting 
1 
Select AZ ([Use AZ1] or [Use AZ2]) to be set. 
2  Click on the [Make AZ1] button or the [Make AZ2] button.   
The cursor enters the AZ creation mode. 
 
3  Set [Start Angle] by turning the EBL dial.   
4  Set [Start Distance] by turning the VRM dial.   
5  Press the EBL dial and the VRM dial. 
6  Set [End Angle] by turning the EBL dial.   
7  Set [End Distance] by turning the VRM dial.   
8  Press the EBL dial.