14-9 
Section 14 Adjusting and Setting up Equipment (for Services)
 
 
 
 
 
 
14.2.3.4  Adjusting a performance monitor of a Solid State Radar 
(NKE-1632/2632)   
Use the [Performance Monitor (SSR)] dialogue. 
Perform the following adjustments based on the transmitting/receiving attenuator value as the 
reference.   
 
Memo 
Do not change the values that are set in the [Monitor Range] input box and the [RX Monitor Gain] 
input box.   
 
Adjusting a monitor reception level 
Adjust the circuit for monitoring the radar equipment reception performance. 
1  Click on the [Monitor Sector] (transmission monitor timing adjustment value) input 
box.   
A numeric value input keyboard is displayed. 
2  Input a setting value in the input box so that the maximum value is displayed in [RX 
Level] (received signal attenuation value).   
For the method of using the numeric value input keyboard, refer to "3.19.2 Name and function 
of each section of the keyboard". 
3  Click on the [RX Monitor Adjustment] (received signal monitor adjustment value).     
A numeric value input keyboard is displayed. 
4  Input a setting value (0 to 127) so that [0.0±1.0dB] is displayed in [RX Level] (received 
signal attenuation value).   
For the method of using the numeric value input keyboard, refer to "3.19.2 Name and function 
of each section of the keyboard". 
 
 
Adjusting a monitor transmission level 
Adjust the circuit for monitoring the radar equipment transmission performance. 
1  Click on the [TX Monitor Adjustment] (transmission signal monitor adjustment value) 
input box.   
A numeric value input keyboard is displayed. 
2  Input a setting value in the input box so that [0.0±1.0dB] is displayed in [TX Level] 
(transmission signal attenuation value). (0~127)   
For the method of using the numeric value input keyboard, refer to "3.19.2 Name and function 
of each section of the keyboard".