14.3.2.3  To change the communication settings of the serial port 
Display the [Detail] dialogue by clicking on the [Detail] button of the serial port that is enabled.   
 
The setting targets can be checked with the [Source Device] display, the [Terminal] display, and the 
[Sensor] display ([Gyro Sensor] display and the [Log Sensor] display when NSK is selected).   
Set the items that are shown in the following table and click on the [Set] button.   
 
Baud Rate  Selects the baud rate of the serial port on the combo 
box. 
Selectable baud rates 
vary depending on the 
serial port (refer to 
"Selectable baud rates"). 
Stop Bits  Selects the stop bit length of the serial port from the 
combo box.   
1 / 2 
Checksum  Selects the check box and enable the checksum of the 
sentence of the corresponding serial port. 
To enable: Select. 
Data Length  Selects the data length of the corresponding serial port 
5 / 6 / 7 / 8 
Buffer Size  Enters the buffer size of the corresponding serial port 
0 to 10240 byte 
Parity  Selects the parity of the corresponding serial port from 
None / Odd / Even 
Time Out  Enters the time-out duration of the corresponding 
0 to 999 s 
Sentence  Specifies the alert sentence type. 
When "-" is selected, no alert is selected. 
- / ALR / ALF 
Transmit Interval  Displayed only when [Alert (to BNWAS)] is selected as 
the sensor. 
Set an alert transmission interval within the range from 
1 to 30 
HBT check box  Displayed in the case other than the case where [Alert 
(to BNWAS)] is selected as the sensor.   
Enables/disables the setting of HBT transmission 
interval.   
To enable: Select. 
To disable: Clear. 
Transmit Interval  Sets the HBT transmission interval within the range 
from 1 second to 30 seconds. 
1 to 30 
 
Selectable baud rates 
 
Serial point on RPU 
1200/2400/4800/9600/19200/38400 
Serial port on the built-in SLC 
2400/4800/9600/19200/38400 
CH1-8  2400/4800/9600 
2400/4800/9600/19200/38400