Section 12 Setting up Alerts  12-8 
 
12.7  Setting up Alert Processing 
[Operation procedure] 
Open the [AMS] dialogue by performing the following menu operations. 
[Menu] button → Alert → AMS 
 
In this dialogue, the time to activate the action at the next stage when acknowledge is not performed 
for an alert can be set up. 
 
Enter a wait time up to the issuing of an alert of the next stage in each [Time Limit].   
[Reactivation of Silenced Alert]
[Time Limit]:   
Set, in a range between 0 and 60 s., the time required to reactivate the alert sound that was silenced 
temporarily. 
[Transfer to BNWAS]
[Time Limit]: 
When a BNWAS (Bridge Navigational Watch Alarm System) is connected, specify the time to transfer 
an unacknowledged alert to the BNWAS in a range between 0 and 60 s. 
[Repetition of UNACK Warning]
[Time Limit]: 
Specify the time to regenerate an unacknowledged warning as an alert sound in a range between 0 
and 300 s. A warning will be generated repeatedly until it is acknowledged.