15-25 Section 15 Maintenance & Inspection
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
23
24
24
26
27
4 Remove the transmitter-receiver unit.
Loosen five hexagon head bolts (M5×16).
Slide the transmitter-receiver unit to the
upper side, and then remove it.
5 Replace the magnetron.
Remove two screws (M4×10), and
remove the magnetron cable.
Use a shielded screwdriver for this
work. Contact with metal (tools) can
cause performance degradation in
the magnetron.
Remove four screws (M4) in total on the
front and rear of the magnetron, and
remove the magnetron.
Use caution not to lose the nut plate.
Secure the replacement magnetron.
Pay attention to the position (yellow and
green) where magnetron and pulse
transformer cables are secured.
After replacing the magnetron, reassemble the unit by following the same steps in reverse
order.
Do not forget to tighten the bolts and screws, and do not forget to reconnect the cables.
Turn On the safety switch and confirm if the equipment operates properly.
The above steps complete the magnetron replacement procedure.